久久国产99欧美精品_亚洲AⅤ无码日韩AV妖精_国产特黄视频在线_欧美男男激情同性videos_95精品国产自产_亚洲一区二区三区无码大片_影音先锋在线资源在线观看_91免费视频在线网址_免费无码性爱高潮精品_亚洲高清欧美高清

Focus on sodium hypochlorite/chlorine dioxide generator manufacturer for 20 years

Your Current Location : Home > Products > Sodium hypochlorite generator (salt water type)

Sodium hypochlorite generator (salt water type)

Features:

The sodium hypochlorite solution generated by electrolysis of brine is used and produced without any by-products, and it does not affect the water quality and safety. With the improvement of the introduction of new technology, the Ou Rui brand sodium hypochlorite generator is unique in domestic technology, with a novel and unique appearance of high automation, high integration, and a number of product patents are applied.

Order

Service Hotline:

+86-400-832-6598
Product Description

The principle of sodium hypochlorite sterilization

The main action of sodium hypochlorite disinfection is to form hypochlorous acid through its hydrolysis, and hypochlorous acid is further decomposed to form new ecological oxygen [O]. The extremely strong oxidizing nature of the new ecological oxygen denatures the proteins and other substances on bacteria and viruses. , Thereby lethal pathogenic microorganisms. Secondly, in the process of sterilization and virus killing, hypochlorous acid can not only act on the cell wall and virus shell, but also because the hypochlorous acid molecule is small and has no charge, it can also penetrate into the bacteria (virus) body and interact with the bacteria (virus) body. Organic polymers such as proteins, nucleic acids and enzymes undergo oxidation reactions to kill pathogenic microorganisms. Third, the chloride ions produced by hypochlorous acid can also significantly change the osmotic pressure of bacteria and virions, causing cells to lose activity and die.


Summary of the principle of sodium hypochlorite generator

The main reaction process of sodium hypochlorite generator electrolysis can be expressed by the following equation:

NaCl+ H2O = NaClO + H2↑

Electrode reaction: anode: 2Cl--2e- → Cl2 cathode: 2H2O + 2e- → H2 + OH-

Solution reaction: 2NaOH + Cl2 → NaCl + NaClO + H2O

The electrolysis process of the electrolytic brine type sodium hypochlorite generator is an electrochemical reaction process. Its only raw materials are salt and water. The sodium hypochlorite solution is made of pure quality. Although the chemical principle is simple, there are many technical indicators that affect the economy. So sodium hypochlorite occurs The design of the electrolysis electrode of the electrolytic device should consider various factors, and design and manufacture according to the characteristics of compact and reasonable structure, energy-saving operation, convenient operation and maintenance, high reliability of operation, and long service life of the equipment. The sodium hypochlorite solution is accurately dosed, safe to operate, easy to use, easy to store, non-toxic to the environment, and there is no air leakage, and it can be dosed under any environmental working conditions.


System unit composition:

1. Soft water unit; 2. Saturated brine preparation unit; 3. Dilute brine proportioning unit; 4. Electrode electrolysis assembly unit; 5. Rectifier power supply unit;

6. Pickling unit; 7. Control system unit; 8. Hydrogen exhaust unit; 9. Storage unit;    10. Dosing unit;


Technical extension:

The Internet of Things realizes logistics network communication, remote real-time display or intervention of equipment working status, remote monitoring and diagnosis.


Features:

The on-site installation is quick, and the installation is completed in only 4 hours if the conditions are met. On-site installation only requires 4 steps:

(1) Connect to the tap water pipeline;

(2) Switch on the power supply;

(3) Connect the chlorination pipeline;

(4) Install hydrogen exhaust pipe


Application areas:

Municipal

Water supply company

Safe drinking water in rural areas

Centralized water supply

Pressure disinfection of the secondary water supply in the community

Hospital sewage disinfection

Agriculture

Livestock breeding

Product Manual
Technical Parameters

Model

Available chlorine productiong/h

Suitable water supply m3/d Surface water/ground water

Solution concentrationg/L

Installed powerkw

Area m2

RN-100

100

0-1200/2400

≥8

0.55

1.56m2

RN-200

200

0-2400/4800

≥8

1.2

1.56m2

RN-300

300

0-3600/7200

≥8

1.8

1.56m2

RN-400

400

0-4800/9600

≥8

2.5

1.56m2

RN-500

500

0-6000/12000

≥8

3.0

1.56m2

RN-600

600

0-7200/14400

≥8

3.6

1.56m2

RN-800

800

0-9600/19200

≥8

4.8

1.56m2

Water supply volume remarks

This is a conventional parameter: surface water available chlorine is added at 2g/t, groundwater available chlorine at 1g/t; special conditions can be selected separately.

Equipment size

780×2000×1500

Salt consumption Kg/kg

3.1

DC power consumption kw.h/kg

3.8

AC power consumption kw.h/kg

4.5

Detailed parameters and technical solutions can be consulted with the company or sales staff (no notice will be given for product technical upgrades)

Flow Chart

Order Online

Advisory Message Leave the question you want to consult and the staff will get in touch with you in time